What is behind cold air from your vents when the heat is on, what you can check yourself, and which causes need a professional.
Cold air from your vents when the heat is on is one of the most common calls we get once the first cold front hits San Antonio. Here are the seven causes we see most often, starting with the ones you can check yourself.
If the fan is set to On, the blower runs nonstop, including between heating cycles, and pushes room-temperature air through the vents. Switch the fan to Auto and make sure the system is set to Heat with the temperature set a few degrees above the room.
Many gas furnaces blow cool air for the first minute or two while the heat exchanger warms up. If the air turns warm after a couple of minutes, that is normal. If it stays cold, keep reading.
A clogged filter chokes airflow, which can make the furnace overheat and shut the burners off as a safety measure while the fan keeps blowing. Replace the filter if it looks gray or dusty. See how often to change your filter.
This is one of the most common causes we find on the first cold night. After months of sitting idle, the flame sensor gets coated and cannot tell the furnace the burners lit, so the furnace shuts the gas off a few seconds after it starts. A tech can clean or replace it quickly.
If the ignitor is cracked or the pilot light is out, the burners never light and the blower moves unheated air. Ignitors wear out over time and often fail at the start of the season.
If the gas valve is off or there is a supply issue, the furnace cannot make heat. If you smell gas at any point, leave the house and call your gas utility or 911 from outside before doing anything else.
Heat pumps periodically run a defrost cycle in cold weather and can blow cooler air for a few minutes. If it keeps blowing cold air, the system may be low on refrigerant or have a bad reversing valve, which needs a technician.
Quick checklist: set the thermostat to Heat and the fan to Auto, replace the filter, and make sure the furnace power switch and breaker are on. If it still blows cold air, the cause is likely a part that needs a pro.
Flame sensors, ignitors, gas valves, and heat pump refrigerant issues need a licensed technician. Our $129 diagnostic finds the exact cause, and that fee is waived if you move forward with the repair. We are open 24/7 with no after-hours upcharge, so call any time. 24/7 emergency heating repair →
Prevent it next year: a fall furnace tune-up cleans the flame sensor and tests the ignitor before you need heat. This November, get a full furnace + AC tune-up for $139.99. See the November special →
The most common causes are a thermostat fan set to On, a dirty filter, a dirty flame sensor, a failed ignitor, or a gas supply problem. Heat pumps can also blow cool air during defrost or when low on refrigerant.
Yes, for a minute or two while it warms up. If the air stays cold longer than that, something needs attention.
It depends on the cause. Our $129 diagnostic finds the exact issue, and the fee is waived if you move forward with the repair. You get a clear price before any work begins.